EDN首页   博客首页

日志档案

发表于 2008-9-28 10:07:49

0

标签: zigbee  cc2430  

如何读取LEMonitor.log信息

 如何读取LEMonitor.log信息
 Rcikli 发表于 2008-4-15 14:27:00

03:03:19:515 |<--| 0x0000 |PING_REQUEST       |

03:03:19:531 |-->| 0x5211 |BLIND_RSP          |01 A3 00 47 00 01 F6 50 9E 00 60 00 41

03:03:19:531 |-->| 0x0000 |PING_RESPONSE      |

03:03:19:531 |<--| 0x0000 |GET_DEVICE_INFO    |

03:03:19:562 |-->| 0x0003 |BLIND_RSP          |00 30 01 0F 00 03 B8 3C 36 01 00 00 37

03:03:19:671 |-->| 0x0000 |DEV_INFO_RSP       |00 17 16 15 14 13 12 12 A1 00 00 01 09 06 00 01 14 3E 28 7B 3C B8 50 F5 65 32 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

03:03:19:796 |-->| 0x01AA |BLIND_RSP          |00 53 00 3D 00 04 53 54 52 00 60 00 47

03:03:19:828 |-->| 0x047A |BLIND_RSP          |00 23 00 55 00 04 90 68 00 00 60 00 43

03:03:19:828 |-->| 0x4A2D |BLIND_RSP          |01 29 01 52 00 01 5F 03 36 01 60 00 3A

03:03:19:937 |-->| 0x1E56 |BLIND_RSP          |00 E4 00 4F 00 04 02 00 EA 00 60 00 3A

03:03:20:406 |-->| 0x0090 |BLIND_RSP          |01 DB 00 11 00 01 F6 50 9E 00 60 00 4A

03:03:20:484 |-->| 0x5184 |BLIND_RSP          |00 7A 01 0A 00 05 3E 14 88 01 00 00 34

03:03:20:484 |-->| 0x0090 |BLIND_RSP          |01 DB 00 11 00 01 F6 50 9E 00 60 00 4A

03:03:20:656 |-->| 0x14CD |BLIND_RSP          |00 00 00 31 00 05 3F 14 00 00 00 00 3C

 

一、各组数据所表示的含义:

|00 00表示整行数据准确可用,01表示数据不准确;

00 00:当前移动点的X16进制坐标,低位在前,高位在后;求实际坐标的方法是将16进制转回10进制,再将所得的数除4

31 00:当前移动点的Y16进制坐标,低位在前,高位在后;求实际坐标的方法是将16进制转回10进制,再将所得的数除4。;

05能与当前移动点通信的REF的数目

3F 14:离当前移动点最近的那个REF的地址,低位在前,高位在后;

00 00:离当前移动点最近的那个REFX坐标16进制坐标,低位在前,高位在后;

00 00:离当前移动点最近的那个REFY坐标16进制坐标,低位在前,高位在后;

3C  离当前移动点最近的那个REFRSSI

系统分类: 嵌入式   |   用户分类: 无分类   |   来源: 原创   |   【推荐给朋友】   |   【添加到收藏夹】

    阅读(100)    回复(0)  

投一票您将和博主都有获奖机会!